Automatic Oxygen Bomb Calorimeter: Precision Calorimetry for Energy Measurement

2025.01.28

The ATC 300A Automatic Oxygen Bomb Calorimeter is a precision instrument designed to accurately measure the calorific value of fuels. Known for its fast and reliable results, this tool is indispensable across various industries. Equipped with a high-precision temperature control system, the ATC 300A ensures consistent performance and dependable outcomes. As the need for accurate energy measurement grows in sectors such as power generation, research, and fuel testing, instruments like the ATC 300A play a critical role in supporting combustion analysis and fuel efficiency studies. This makes it an essential asset for effective energy measurement and analysis.

What is an Automatic Oxygen Bomb Calorimeter?

Definition and Primary Function

The Automatic Oxygen Bomb Calorimeter is a precise instrument used to determine the calorific value of various substances. It is particularly effective for measuring the energy content of solid fuels like coal, straw, and petroleum, as well as liquids such as petroleum-based fuels. This device plays a crucial role in industries like thermal power, cement production, coal mining, and new energy development.

Structure of the Oxygen Bomb Calorimeter

The Oxygen Bomb Calorimeter consists of several key components:

  • Inner Chamber: Houses the oxygen bomb, which contains the fuel sample and water.
  • Outer Chamber: Provides insulation to ensure stable test conditions.
  • Stirring Device: Ensures uniform mixing of water for accurate temperature measurements.
  • Temperature Sensor: Tracks temperature changes during testing.
  • Data Processing System: Records data and calculates the heat generated during combustion.

Key Features and Advancements of ATC 300A

Automatic Functions

The ATC 300A boasts a range of automated features designed for ease of use and precision:

  • Automatic lifting and recognition of the bomb’s serial number.
  • Automatic filling and release of oxygen, along with pressure detection.
  • Automated measurement of water volume and handling of water inlet and drainage in both the inner and outer barrels.

These features minimize manual intervention, reduce errors, and ensure accurate test results.

Cooling and Temperature Control

Equipped with a specialized semiconductor cooling system, the ATC 300A uses circulating water and a high-efficiency filter to control temperature trends. This system helps achieve thermal equilibrium quickly, reducing environmental interference and improving insulation for better heating and cooling.

Ignition and Protection Features

The ATC 300A includes automatic ignition wire detection and short-circuit protection in the ignition circuit, enhancing safety and reliability during testing.

User Interface and Data Management

The ATC 300A features a color touchscreen LCD that displays real-time data and graphical curves, simplifying the testing process. The device automatically corrects data, offering three types of calorific values: higher heating value, lower heating value, and bomb calorific value. It adjusts for heat produced by ignition wire combustion and the calorific value of other substances like nitric acid, sulfur, and hydrocarbons.

Advanced serial port technology allows for multi-control of multiple units, preventing interference between experiments.The system supports automatic generation and storage of charts and data, as well as the retrieval of historical data.A dual control setup integrates the touchscreen with a PC-based operating system for enhanced monitoring and safety.

Applications in Various Industries

Coal Testing

The calorimeter plays a vital role in measuring the calorific value of coal, a key parameter for evaluating its quality. This data is essential for determining coal’s energy potential and economic value, influencing decisions related to procurement, sales, and energy planning.

Feed Oils

In animal feed production, the calorimeter is used to measure the energy content of feed oils. Accurate energy measurement ensures that animals receive the necessary nutrients and energy for optimal growth and health.

Petroleum Testing

The Oxygen Bomb Calorimeter is widely used to measure the calorific values of anhydrous petroleum products such as gasoline, jet fuel, diesel, and heavy oils. It is crucial for evaluating the quality of petroleum fuels and is also employed in thermal energy management and internal combustion engine efficiency studies.

Advantages Over Traditional Calorimetry

Speed and Automation

The ATC 300A offers faster testing with minimal manual effort, significantly improving efficiency. Automation ensures tests are completed more quickly, reducing time and labor costs.

Higher Precision

With advanced technology, the ATC 300A delivers more accurate and repeatable results than traditional methods. This higher precision ensures more reliable data, which is essential for combustion analysis and energy studies.

Increased Safety

The closed system used by the ATC 300A ensures greater safety when handling high-pressure reactions, reducing the risk of accidents and ensuring safe testing conditions.

Reduced Human Error

The automated data collection and reporting features of the ATC 300A minimize the risk of human error, ensuring more consistent and accurate test results compared to manual processes.

Quality Assurance and Compliance

Adherence to International Standards

The ATC 300A complies with several internationally recognized standards, including GB/T 384, GB/T 213, ASTM 4809, and ASTM D240. This adherence ensures the device meets industry-specific requirements and provides reliable performance.

Stringent Quality Control Processes

During manufacturing, the ATC 300A undergoes rigorous quality control procedures to ensure that each unit adheres to high performance standards. This ensures the device’s reliability and accuracy over time.

Calibration Methods

The ATC 300A uses specialized calibration methods to maintain precise accuracy throughout its lifespan. Regular calibration ensures that the device continues to provide reliable results and upholds its performance standards.

Final Words

The ATC 300A Automatic Oxygen Bomb Calorimeter is a high-performance, precision instrument widely used across various industries. It provides accurate measurements of the calorific value of materials such as coal, feed oils, and petroleum, allowing for a thorough assessment of energy content and quality. Offering significant advantages over traditional methods, the ATC 300A delivers faster results, enhanced precision, and improved safety. Its automated features minimize human error, ensuring more reliable and consistent data. Additionally, the device adheres to stringent quality control processes and complies with international standards, guaranteeing dependable performance. Whether for coal procurement, fuel testing, or other energy-related applications, the ATC 300A is a trusted solution for accurate energy measurements.